Search results for "Ablation Techniques"
showing 10 items of 16 documents
Analysis of the morphology and composition of tooth apices apicectomized using three different ablation techniques.
2011
Objectives: To investigate apicectomies performed using burs, a CO2 laser or an Er:YAG laser and to evaluate the following aspects: morphology of apicectomized surfaces, presence of failures at the dentin/obturation material interface (marginal fit) of the apical portions of the root canals, and the proportions of chemical elements in the apicectomized surfaces. Study design: Twenty-four teeth were divided into three groups of eight and each group underwent apicectomy by one of three different ablation techniques: bur, CO2 laser or Er:YAG laser. The morphology of the apicectomized surfaces was then analyzed using scanning electron microscopy and their chemical composition was analyzed by en…
The Intention-to-Treat Effect of Bridging Treatments in the Setting of Milan Criteria–In Patients Waiting for Liver Transplantation
2019
In patients with hepatocellular carcinoma (HCC) meeting the Milan criteria (MC), the benefit of locoregional therapies (LRTs) in the context of liver transplantation (LT) is still debated. Initial biases in the selection between treated and untreated patients have yielded conflicting reported results. The study aimed to identify, using a competing risk analysis, risk factors for HCC-dependent LT failure, defined as pretransplant tumor-related delisting or posttransplant recurrence. The study was registered at www.clinicaltrials.gov (identification number NCT03723304). In order to offset the initial limitations of the investigated population, an inverse probability of treatment weighting (IP…
Pattern of macrovascular invasion in hepatocellular carcinoma
2021
Background and aims: In patients with hepatocellular carcinoma (HCC), macrovascular invasion (MaVI) limits treatment options and decreases survival. Detailed data on the relationship between MaVI extension and patients' characteristics, and its impact on patients' outcome are limited. We evaluated the prevalence and extension of MaVI in a large cohort of consecutive HCC patients, analysing its association with liver disease and tumour characteristics, as well as with treatments performed and patients' survival. Methods: We analysed data of 4774 patients diagnosed with HCC recorded in the Italian Liver Cancer (ITA.LI.CA) database (2008-2018). Recursive partition analysis (RPA) was performed …
Release kinetics of early ischaemic biomarkers in a clinical model of acute myocardial infarction
2014
ObjectiveTo determine the release kinetics of different biomarkers with potential as novel early ischaemic biomarkers in patients with acute coronary syndrome (ACS); it is difficult to establish the detailed release kinetics in patients with acute myocardial infarction (AMI).MethodsWe analysed the release kinetics of soluble fms-like tyrosine kinase (sFlt-1), ischaemia modified albumin (IMA), and heart-type fatty acid binding protein (hFABP) in patients with hypertrophic obstructive cardiomyopathy who were undergoing transcoronary ablation of septal hypertrophy (TASH), a procedure mimicking AMI. Consecutive patients (n=21) undergoing TASH were included. Blood samples were collected before T…
Factors affecting basket catheter detection of real and phantom rotors in the atria: A computational study
2018
[EN] Anatomically based procedures to ablate atrial fibrillation (AF) are often successful in terminating paroxysmal AF. However, the ability to terminate persistent AF remains disappointing. New mechanistic approaches use multiple-electrode basket catheter mapping to localize and target AF drivers in the form of rotors but significant concerns remain about their accuracy. We aimed to evaluate how electrode-endocardium distance, far-field sources and inter-electrode distance affect the accuracy of localizing rotors. Sustained rotor activation of the atria was simulated numerically and mapped using a virtual basket catheter with varying electrode densities placed at different positions withi…
Sr-isotope analysis of speleothems by LA-MC-ICP-MS: High temporal resolution and fast data acquisition
2017
Speleothems are well established climate archives. A wide array of geochemical proxies, including stable isotopes and trace elements are present within speleothems to reconstruct past climate variability. However, each proxy is influenced by multiple factors, often hampering robust interpretation. Sr isotope ratios (87Sr/86Sr) can provide useful information about water residence time and water mixing in the host rock, as they are not fractionated during calcite precipitation. Laser ablation multi-collector-inductively coupled plasma mass spectrometry (LA-MC-ICP-MS) has rarely been used for determination of Sr isotope signatures in speleothems, as speleothems often do not possess appropriate…
Posterior cordotomy in bilateral vocal cord paralysis using monopolar microelectrodes and radiofrequency in 18 patient
2017
Endovenous ablation of refluxing saphenous and perforating veins.
2017
Abstract. Since the end of the nineties endovenous thermal ablation and more recently non-thermal, non-tumescent techniques have been developed and improved. Until now, because of their favourable side effect profile in conjunction to sustained efficacy, in many countries they already replaced high ligation and stripping in the treatment of refluxing saphenous veins as well as for treatment of perforators and selected tributaries. Now, studies and comparative trials are available with long-term follow-ups for most of the techniques, providing valid data on occlusion and reflux rates, side effect profiles, and health related quality of life.
Impact of monitoring on detection of arrhythmia recurrences in the ESC-EHRA EORP atrial fibrillation ablation long-term registry
2019
Abstract Aims Monitoring of patients after ablation had wide variations in the ESC-EHRA atrial fibrillation ablation long-term (AFA-LT) registry. We aimed to compare four different monitoring strategies after catheter AF ablation. Methods and results The ESC-EHRA AFA-LT registry included 3593 patients who underwent ablation. Arrhythmia monitoring during follow-up was performed by 12-lead electrocardiogram (ECG), Holter ECG, trans-telephonic ECG monitoring (TTMON), or an implanted cardiac monitoring (ICM) system. Patients were selected to a given monitoring group according to the most extensive ECG tool used in each of them. Comparison of the probability of freedom from recurrences was perfo…
Microwave-induced thermoablation with Amica-probe is a safe and reproducible method to treat solid renal masses: results from a phase I study.
2012
Microwave thermal ablation (MWTA) could be considered in the future for treating small solid renal masses. The aim of the present study was to determine both the tolerability of the new Amica-probe applicator-induced MWTA used in vivo on patients with solid renal masses and the effects of heating on renal tumors and normal renal parenchyma. Fourteen patients with renal masses eligible for open radical nephrectomy were enrolled in this phase I study. All patients underwent MWTA of renal masses during the open surgery procedure before clamping of renal vascular pedicle. The effects of MWTA on patients' coagulation and tumor/renal vasculature were investigated. The histological effects of MWTA…